  "abstract": "Size an exhaust fan for the bigger of two numbers: one air change a minute (CFM = tent volume in ft³) or the heat it must carry out (CFM = BTU/h ÷ (1.08 × temperature rise in °F)). For a 4×4×6.5 ft tent that's 104 CFM for air changes but about 190 CFM to carry 600 W of heat out at a 10 °F rise. Then allow for the carbon filter, ducting and bends using the fan's curve. Use passive intakes about 2–3 times the exhaust duct area for slight negative pressure.",