  "abstract": "Your cooling load is every watt you plug in, times 3.412 BTU/h, plus heat through walls and from people. Lights, drivers, fans, pumps and the dehumidifier all count. Plants don't add heat; they turn some of it into humidity, and a dehumidifier turns it back into heat. A sealed 10×10 ft room with about 3,300 W of LED needs roughly 16,000 BTU/h (1.3 tons) of cooling with dehumidification, before a 10–20% margin. Prefer a mini-split to a single-hose portable unit.",